Possess battery pack voltage, current, temperature acquisition and monitoring functions;
It can provide protection functions such as overcharge, overdischarge, overcurrent, high temperature, low temperature, short circuit, and abnormal internal communication for the battery pack;
It has the functions of accurate SOC measurement and SOH health status statistics during the charging and discharging process;
Possess the cell equalization function during the charging process;
With a battery data storage unit, it can classify and store battery alarms and operating data;
It has RS485 communication, supports the MODBUS protocol of the power exchange cabinet, and can communicate with Tianbangda host computer to realize the function of monitoring data and configuring parameters;
This product can be equipped with a 4G wireless communication module. After the wireless module is equipped with a SIM card, the battery pack monitoring information can be uploaded to the monitoring background to monitor the battery information.
Support GPS and Beidou dual-mode positioning;
With functions such as remote upgrade and parameter modification;
This product can be equipped with BLE4.2 Bluetooth module, supports GATT protocol, the battery is used as a server, and the power exchange cabinet/mobiles APP is used as a client to obtain battery device information.
Working temperature | -20℃~+65℃ | |||||
Cooling method | Natural heat dissipation | |||||
Dimensions (L*W*Dmm) | Special car, can be customized | |||||
Protection level | IP67 (Complete with PACK) |
Battery voltage | UP 60V/72V | |||||
Rated charge/discharge power | UP 3000W (can be customized) |
Wireless communication | 4G/BT/dual-mode positioning/NB | |||||
Communication interface | CAN/RS485; Line Communication |
Support battery type | 13-25s, lithium iron phosphate UP 25S/ternary UP21S (cascade AFE) | |||||
Rated battery voltage | UP 72V | |||||
Support battery capacity | UP 50Ah/Customized | |||||
Alarm and protection | Overvoltage, undervoltage, short circuit, overtemperature, low temperature protection, etc. |
Discharge current limit | UP 1.5C | |||||
Secondary protection | Onboard level high current controllable fuse | |||||
Power terminal control | Positive control to reduce isolation devices | |||||
Communication diagnosis | UDS Diagnostic Protocol | |||||
Current detection | UDS Diagnostic Protocol | |||||
SOX super algorithm | Dynamic discharge voltage calibration, charge calibration | |||||
Anti-ignition | Hardware plus software strategy, never start a fire |
Model | Share | Tower 3.0 | Tower 4.0 | |||
Basic parameters | 4815 | 4824/4830 | 4825/4830 | 6020/6030 | UP 4850 | UP 6050 |
Power type | Share battery swap | |||||
Number of voltage acquisition strings | 15 skewers | 16 skewers | 16 skewers | 20 skewers | 16 skewers | 20 skewers |
Temperature sensor | 6-way (4-way/5-way battery/1-way environment/1-way MOS) | |||||
External communication | Dual RS485 | |||||
Flow capacity | 15A | 24A/30A | 25A | 30A | 50A | 50A |
Data storage | 1000 gradually replaced | |||||
Maximum detection voltage | 60V | 60V | 60V | 72V | 60V | 72V |
SOC error | ≤5% | |||||
Range of working temperature | -20℃~70℃ | |||||
Temperature acquisition accuracy | 50% of the range above the temperature display error ≤ 2 ℃ | |||||
Current acquisition accuracy | Charge and discharge current error ≤ 2% above 50% of the range | |||||
Anti-ignition | have | |||||
Discharge current limiting | \ | \ | have | |||
4G wireless communication | \ | Yes, supports the standard TCP communication protocol for tower power replacement, supports remote modification of BMS parameters in the background, and has stable and reliable remote self-upgrade and BMS upgrade capabilities | ||||
Bluetooth communication | \ | have |